{"id":872,"date":"2022-01-07T13:46:24","date_gmt":"2022-01-07T13:46:24","guid":{"rendered":"https:\/\/www.geotherma.be\/produits\/forages\/"},"modified":"2023-09-29T13:44:34","modified_gmt":"2023-09-29T13:44:34","slug":"forages","status":"publish","type":"page","link":"https:\/\/www.geotherma.be\/fr\/produits\/forages\/","title":{"rendered":"Forages"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-page\" data-elementor-id=\"872\" class=\"elementor elementor-872 elementor-40\" data-elementor-post-type=\"page\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-45c9baa elementor-section-height-min-height elementor-section-boxed elementor-section-height-default elementor-section-items-middle\" data-id=\"45c9baa\" data-element_type=\"section\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-e2af77a\" data-id=\"e2af77a\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-abe3d41 elementor-widget elementor-widget-heading\" data-id=\"abe3d41\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">Forages pour pompes \u00e0 chaleur g\u00e9othermiques<\/h1>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-03040e9 elementor-widget elementor-widget-heading\" data-id=\"03040e9\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<span class=\"elementor-heading-title elementor-size-default\">GeoTherma ne r\u00e9alise pas seulement l\u2019\u00e9tude pr\u00e9liminaire pour une pompe \u00e0 chaleur g\u00e9othermique, mais aussi le forage vertical du terrain. Vous souhaitez un prix de forage adapt\u00e9 \u00e0 vos besoins ? Contactez nous !<\/span>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7175f3b elementor-widget__width-auto elementor-widget elementor-widget-button\" data-id=\"7175f3b\" data-element_type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-button-wrapper\">\n\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"https:\/\/www.geotherma.be\/fr\/pompes-a-chaleur\/pompes-a-chaleur-geothermiques\/pompes-a-chaleur-geothermiques-captation-verticale\/\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">En savoir plus sur l'\u00e9nergie g\u00e9othermique<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-58078e5 elementor-widget__width-auto elementor-widget elementor-widget-button\" data-id=\"58078e5\" data-element_type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-button-wrapper\">\n\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"https:\/\/www.geotherma.be\/fr\/contact\/\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Contactez nous<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-fac8bda\" data-id=\"fac8bda\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-228a810 elementor-widget elementor-widget-image\" data-id=\"228a810\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"1200\" height=\"796\" src=\"https:\/\/www.geotherma.be\/wp-content\/uploads\/2023\/08\/verticale-captatie.png\" class=\"attachment-1536x1536 size-1536x1536 wp-image-3845\" alt=\"verticale captatie\" srcset=\"https:\/\/www.geotherma.be\/wp-content\/uploads\/2023\/08\/verticale-captatie.png 1200w, https:\/\/www.geotherma.be\/wp-content\/uploads\/2023\/08\/verticale-captatie-300x199.png 300w, https:\/\/www.geotherma.be\/wp-content\/uploads\/2023\/08\/verticale-captatie-1024x679.png 1024w, https:\/\/www.geotherma.be\/wp-content\/uploads\/2023\/08\/verticale-captatie-768x509.png 768w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-48893ee elementor-reverse-tablet elementor-reverse-mobile elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"48893ee\" data-element_type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-11e8ac1\" data-id=\"11e8ac1\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-3e0cc0c elementor-widget elementor-widget-text-editor\" data-id=\"3e0cc0c\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2 style=\"font-size: 2.2em;\"><span style=\"color: #f7941e;\">Forage g\u00e9othermique<\/span><br \/><span style=\"color: #00b084;\">par GeoTherma<\/span><\/h2>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4cc2f8c elementor-widget elementor-widget-text-editor\" data-id=\"4cc2f8c\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>GeoTherma con\u00e7oit et fournit des syst\u00e8mes d\u2019\u00e9nergie g\u00e9othermique bas\u00e9s sur des \u00e9changeurs de chaleur verticaux ferm\u00e9s destin\u00e9s \u00e0 des pompes \u00e0 chaleur g\u00e9othermiques.<\/p>\n<p>Le nombre et la profondeur des forages sont d\u00e9termin\u00e9s en fonction de la puissance requise, de la demande calorifique annuelle, de la charge de refroidissement et des donn\u00e9es du sous-sol.<\/p>\n<p>Par trou de forage, les \u00e9changeurs de chaleur g\u00e9othermiques sont constitu\u00e9s d\u2019une double boucle en U de tuyaux en PEHD de 25 mm de diam\u00e8tre, qui sont connect\u00e9s en parall\u00e8le et \u00e0 l\u2019abri du gel avec les \u00e9changeurs des autres trous de forage, via des boucles de Tichelmann.<\/p>\n<p>L\u2019espacement minimal entre 2 forages est fix\u00e9 \u00e0 7 m.<\/p>\n<p>Le trou de forage lui-m\u00eame est termin\u00e9 avec du gravier et des bouchons d\u2019argile, ou rempli d\u2019un grout thermique dans les cas o\u00f9 un permis environnemental est requis.<\/p>\n<p>Enfin, le syst\u00e8me d\u2019\u00e9nergie g\u00e9othermique est rinc\u00e9 et rempli d\u2019un m\u00e9lange eau-glycol \u00e0 base de monopropyl\u00e8ne glycol, qui assurera le transport de l\u2019\u00e9nergie g\u00e9othermique vers la pompe \u00e0 chaleur.<\/p>\n<p>Les crit\u00e8res qui d\u00e9terminent si la demande de permis environnemental est obligatoire ou non peuvent varier consid\u00e9rablement d\u2019une localit\u00e9 \u00e0 une autre ; ceci est toujours pris en compte lors de la phase d\u2019\u00e9tude. Les documents exig\u00e9s pour la demande peuvent \u00eatre obtenus pr\u00e9remplis aupr\u00e8s de GeoTherma.<\/p>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-63dbbc2 elementor-hidden-tablet elementor-hidden-mobile\" data-id=\"63dbbc2\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-85a77b8 elementor-widget elementor-widget-image\" data-id=\"85a77b8\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"309\" height=\"483\" src=\"https:\/\/www.geotherma.be\/wp-content\/uploads\/2021\/12\/Boringen-foto-bij-tekst.jpg\" class=\"attachment-full size-full wp-image-221\" alt=\"geothermische boringen warmtepomp\" srcset=\"https:\/\/www.geotherma.be\/wp-content\/uploads\/2021\/12\/Boringen-foto-bij-tekst.jpg 309w, https:\/\/www.geotherma.be\/wp-content\/uploads\/2021\/12\/Boringen-foto-bij-tekst-192x300.jpg 192w\" sizes=\"(max-width: 309px) 100vw, 309px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-96c3253 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"96c3253\" data-element_type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-78e299d\" data-id=\"78e299d\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-b5351c7 elementor-widget elementor-widget-video\" data-id=\"b5351c7\" data-element_type=\"widget\" data-settings=\"{&quot;youtube_url&quot;:&quot;https:\\\/\\\/www.youtube.com\\\/watch?v=vGR_KssATYg&quot;,&quot;yt_privacy&quot;:&quot;yes&quot;,&quot;lazy_load&quot;:&quot;yes&quot;,&quot;show_image_overlay&quot;:&quot;yes&quot;,&quot;image_overlay&quot;:{&quot;url&quot;:&quot;https:\\\/\\\/www.geotherma.be\\\/wp-content\\\/uploads\\\/2022\\\/05\\\/grondboringen-warmtepomp-thumbnail.jpg&quot;,&quot;id&quot;:1631,&quot;size&quot;:&quot;&quot;,&quot;alt&quot;:&quot;&quot;,&quot;source&quot;:&quot;library&quot;},&quot;video_type&quot;:&quot;youtube&quot;,&quot;controls&quot;:&quot;yes&quot;}\" data-widget_type=\"video.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-wrapper elementor-open-inline\">\n\t\t\t<div class=\"elementor-video\"><\/div>\t\t\t\t<div class=\"elementor-custom-embed-image-overlay\" style=\"background-image: url(https:\/\/www.geotherma.be\/wp-content\/uploads\/2022\/05\/grondboringen-warmtepomp-thumbnail.jpg);\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<div class=\"elementor-custom-embed-play\" role=\"button\" aria-label=\"Lire la vid\u00e9o\" tabindex=\"0\">\n\t\t\t\t\t\t\t<i aria-hidden=\"true\" class=\"eicon-play\"><\/i>\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-0c76016 elementor-section-height-min-height elementor-section-boxed elementor-section-height-default elementor-section-items-middle\" data-id=\"0c76016\" data-element_type=\"section\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t\t\t<div class=\"elementor-background-overlay\"><\/div>\n\t\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-010f53b\" data-id=\"010f53b\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap\">\n\t\t\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-a1c403a elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"a1c403a\" data-element_type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-40e3e2a\" data-id=\"40e3e2a\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-3e76bd6 elementor-widget elementor-widget-text-editor\" data-id=\"3e76bd6\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2 style=\"font-size: 2.2em;\"><span style=\"color: #f7941e;\">Questions fr\u00e9quentes<\/span><br \/><span style=\"color: #00b084;\">sur le forage de puits pour l&rsquo;\u00e9nergie g\u00e9othermique<\/span><\/h2>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8a9111d elementor-widget__width-initial elementor-widget-mobile__width-inherit elementor-widget elementor-widget-text-editor\" data-id=\"8a9111d\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>A quelle profondeur allez-vous forer ?<\/strong><\/p>\n<p>La profondeur de forage d\u00e9pend de diff\u00e9rents facteurs, notamment de la g\u00e9ologie du sous-sol et de la puissance n\u00e9cessaire. Notre d\u00e9partement d&rsquo;ing\u00e9nierie effectue toujours les calculs n\u00e9cessaires pour d\u00e9terminer la profondeur de forage correcte.<\/p>\n<p><strong>Combien de points de forage sont n\u00e9cessaires ?<\/strong><\/p>\n<p>Pour une maison moyenne, deux \u00e0 trois forages g\u00e9othermiques sont n\u00e9cessaires. Selon la taille de la maison, le degr\u00e9 d&rsquo;isolation et d&rsquo;autres facteurs, nous devons pr\u00e9voir des points de forage suppl\u00e9mentaires.<\/p>\n<p><strong>De combien d&rsquo;espace ai-je besoin ?<\/strong><\/p>\n<p>La distance minimale entre deux forages est de 7 m\u00e8tres. Assurez-vous \u00e9galement que notre installation de forage dispose de suffisamment d&rsquo;espace pour atteindre les points de forage.<\/p>\n<p><strong>Combien co\u00fbte un forage g\u00e9othermique ?<\/strong><\/p>\n<p>Le prix est principalement d\u00e9termin\u00e9 par le nombre de forages et la profondeur. \u00c0 cela s&rsquo;ajoute le taux de TVA de 21 % pour les nouvelles constructions et de 6 % pour les r\u00e9novations (maisons priv\u00e9es de plus de 10 ans). Vous souhaitez un prix sur mesure ? Contactez nous !<\/p>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-08f5410 elementor-widget__width-initial elementor-widget-mobile__width-inherit elementor-widget elementor-widget-text-editor\" data-id=\"08f5410\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>Quels sont les avantages des pompes \u00e0 chaleur \u00e0 forage profond ?<\/strong><\/p>\n<p><a href=\"https:\/\/www.geotherma.be\/fr\/pompes-a-chaleur\/pompes-a-chaleur-geothermiques\/pompes-a-chaleur-geothermiques-captation-verticale\/\">Les pompes \u00e0 chaleur \u00e0 captage vertical<\/a> ont le rendement le plus \u00e9lev\u00e9 de toutes les pompes \u00e0 chaleur. En outre, ils ont une grande capacit\u00e9 de refroidissement passif. Il reste donc agr\u00e9able et frais \u00e0 l&rsquo;int\u00e9rieur pendant les chaudes journ\u00e9es d&rsquo;\u00e9t\u00e9.<\/p>\n<p><strong>Les forages g\u00e9othermiques sont-ils nuisibles \u00e0 l&rsquo;environnement ?<\/strong><\/p>\n<p>Non, nos sondages du sol pour les pompes \u00e0 chaleur sont conformes \u00e0 la stricte r\u00e9glementation environnementale belge.<\/p>\n<p><strong>Ces forages peuvent-ils \u00eatre r\u00e9alis\u00e9s dans toute la Belgique ?<\/strong><\/p>\n<p>Oui, GeoTherma r\u00e9alise des forages de pompes \u00e0 chaleur dans toute la Belgique. Il est important de savoir que la composition du sol diff\u00e8re d&rsquo;un endroit \u00e0 l&rsquo;autre. C&rsquo;est pourquoi nous faisons toujours une \u00e9tude pr\u00e9liminaire pour d\u00e9terminer la profondeur du forage. Attention : Dans les zones d&rsquo;extraction d&rsquo;eau, un permis environnemental (classe 2) est requis ou le forage peut \u00eatre totalement interdit. Les g\u00e9oboucles (capture horizontale) constituent ici une bonne alternative.<\/p>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3bf858f elementor-widget elementor-widget-html\" data-id=\"3bf858f\" data-element_type=\"widget\" data-widget_type=\"html.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<script type=\"application\/ld+json\">{\"@context\":\"https:\/\/schema.org\",\"@type\":\"FAQPage\",\"mainEntity\":[{\"@type\":\"Question\",\"name\":\"Hoe diep wordt er geboord?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"De boordiepte is afhankelijk van diverse factoren, waaronder de geologie van de ondergrond en het benodigde vermogen. Onze studiedienst maakt telkens de nodige berekeningen om de juiste boordiepte te bepalen.\"}},{\"@type\":\"Question\",\"name\":\"Hoeveel boorpunten zijn er nodig?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Voor een doorsnee woning zijn er twee \u00e0 drie geothermische boringen nodig. Afhankelijk van de grootte van de woning, de isolatiegraad en andere factoren moeten we bijkomende boorpunten voorzien.\"}},{\"@type\":\"Question\",\"name\":\"Hoeveel plaats heb ik nodig?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"De minimumafstand tussen twee boringen is 7 meter. Zorg er ook voor dat onze boortoren voldoende plaats heeft om de boorpunten te bereiken. \"}},{\"@type\":\"Question\",\"name\":\"Hoeveel kost een geothermische boring?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"De prijs wordt voornamelijk bepaald door het aantal boorputten en de diepte. Daarnaast is er nog het btw-tarief van 21% voor nieuwbouw en 6% voor renovaties (priv\u00e9woningen ouder dan tien jaar). Graag een prijs op maat? Contacteer ons!\"}},{\"@type\":\"Question\",\"name\":\"Wat zijn de voordelen van warmtepompen met een diepteboring?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Warmtepompen met een verticale captatie hebben het hoogste rendement van alle warmtepompen. Bovendien hebben ze een groot passief koelvermogen. Zo blijft het binnen lekker fris tijdens warme zomerdagen. \"}},{\"@type\":\"Question\",\"name\":\"Zijn geothermische boringen schadelijk voor het milieu?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Nee, onze grondboringen voor warmtepompen voldoen aan de strenge Belgische milieuwetgevingen. \"}},{\"@type\":\"Question\",\"name\":\"Kunnen deze boringen in heel Vlaanderen?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Ja, GeoTherma voert warmtepomp boringen uit in Limburg, Vlaams-Brabant, Antwerpen, Oost-Vlaanderen en West-Vlaanderen. Belangrijk om te weten is dat de bodemsamenstelling verschilt per locatie. Daarom maken we steeds een voorstudie om de boordiepte te bepalen. Opgelet: in waterwinningsgebied is een milieuvergunning (klasse 2)  vereist of kunnen boringen helemaal verboden zijn.  Hier zijn Geolussen(horizontale captatie) een goed alternatief.\"}}]}<\/script><!--FAQPage Code Generated by https:\/\/saijogeorge.com\/json-ld-schema-generator\/faq\/-->\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Forages pour pompes \u00e0 chaleur g\u00e9othermiques GeoTherma ne r\u00e9alise pas seulement l\u2019\u00e9tude pr\u00e9liminaire pour une pompe \u00e0 chaleur g\u00e9othermique, mais aussi le forage vertical du terrain. Vous souhaitez un prix de forage adapt\u00e9 \u00e0 vos besoins ? Contactez nous ! En savoir plus sur l&rsquo;\u00e9nergie g\u00e9othermique Contactez nous Forage g\u00e9othermiquepar GeoTherma GeoTherma con\u00e7oit et fournit [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":858,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_jf_save_progress":"","footnotes":""},"class_list":["post-872","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.geotherma.be\/fr\/wp-json\/wp\/v2\/pages\/872","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.geotherma.be\/fr\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.geotherma.be\/fr\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.geotherma.be\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.geotherma.be\/fr\/wp-json\/wp\/v2\/comments?post=872"}],"version-history":[{"count":2,"href":"https:\/\/www.geotherma.be\/fr\/wp-json\/wp\/v2\/pages\/872\/revisions"}],"predecessor-version":[{"id":4309,"href":"https:\/\/www.geotherma.be\/fr\/wp-json\/wp\/v2\/pages\/872\/revisions\/4309"}],"up":[{"embeddable":true,"href":"https:\/\/www.geotherma.be\/fr\/wp-json\/wp\/v2\/pages\/858"}],"wp:attachment":[{"href":"https:\/\/www.geotherma.be\/fr\/wp-json\/wp\/v2\/media?parent=872"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}